Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Intervalo de año de publicación
1.
Braz. dent. sci ; 27(1): 1-11, 2024. tab
Artículo en Inglés | LILACS, BBO - Odontología | ID: biblio-1537767

RESUMEN

Objective: This systematic review aims to compare the clinical longevity of metallic and fiberglass intraradicular posts in teeth with severely compromised crowns, utilizing randomized clinical trials and case reports published in the last eleven years. Material and Methods: The research was conducted on PubMed, Medline, Lilacs, and BBO databases using the first search strategy with the descriptors 'dental posts,' 'longevity,' 'fiberglass-reinforced posts' or 'metallic posts.' The second search strategy involved analyzing the references of articles identified by the first search. Both studies were carried out with stringent inclusion and exclusion criteria. Results: No statistically significant and clinically relevant differences in longevity were observed between metallic and fiberglass posts. Conclusion: The clinical success and durability of the restorative procedure using intraradicular posts primarily depend on the remaining amount around the post (ferrule), the type and position of the tooth in the arch (impacting the masticatory forces exerted on the restored tooth), and the correct application of the cementation technique. It is noteworthy that fiberglass posts offer substantial advantages by presenting a modulus of elasticity similar to dental structure, ensuring a more homogeneous distribution of masticatory forces and reducing the risk of fractures. These findings have practical implications for material selection in restorative procedures involving intraradicular posts.(AU)


Objetivo: Esta revisão sistemática visa comparar a longevidade clínica de pinos intrarradiculares metálicos e de fibra de vidro em dentes com coroas severamente comprometidas, através de estudos clínicos randomizados e relatos de casos, publicados nos últimos onze anos. Material e Métodos: A pesquisa foi conduzida nas bases de dados PubMed, Medline, Lilacs e BBO, utilizando a primeira estratégia de busca com os s 'pinos dentais' e 'longevidade' e 'pinos reforçados com fibra de vidro' ou 'pinos metálicos'. A segunda estratégia de busca consistiu na análise das referências dos artigos identificados pela primeira estratégia. Ambos os estudos foram delineados com critérios rigorosos de inclusão e exclusão. Resultados: Não se constataram diferenças estatisticamente significativas e clinicamente relevantes na longevidade entre pinos metálicos e de fibra de vidro. Conclusão: O êxito clínico e a durabilidade do procedimento restaurador empregando pinos intrarradiculares dependem primordialmente da quantidade de remanescente ao redor do pino (férula), do tipo e posição do dente na arcada (o que impacta nas forças mastigatórias exercidas sobre o dente restaurado) e da aplicação correta da técnica de cimentação.Destaca-se que o pino de fibra de vidro oferece vantagens substanciais ao apresentar módulo de elasticidade similar à estrutura dentária, assegurando uma distribuição mais homogênea das forças mastigatórias e reduzindo o risco de fraturas (AU)


Asunto(s)
Materiales Dentales , Pins Dentales
2.
Restor Dent Endod ; 46(4): e55, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34909419

RESUMEN

OBJECTIVES: The purpose of this systematic review was to collect and discuss the technique of adhesive systems application on dentin substrate under electric current. MATERIALS AND METHODS: The first search strategy was based on data available at PubMed, LILACS, Scielo, Scopus, and Cochrane Library, using a combination of descriptors such as "dentin bond agents OR adhesive system AND electric current OR electrobond" or "dentin bonding agents OR dentin bonding agent application OR adhesive system AND electric current OR electrobond", with no limit regarding the publication year. The second search strategy was based on the articles' references found previously. An additional search strategy was applied that concerned the proposed theme in the SBU-UNICAMP (Unicamp's Library System Institutional Repository). RESULTS: Twelve studies published between 2006 and 2020 were found. The analyses of the selected studies showed that the use of electric current during adhesive systems application on dentin, whether conventional or self-conditioning, increases resinous monomer infiltration in the dentin substrate, which improves the hybridization processes and the bond strength of the restorative material to dentin. CONCLUSIONS: Despite the favorable results related to the use of this technique, there is still no specific protocol for the application of adhesive systems under electric current.

3.
Clin Oral Investig ; 25(9): 5181-5188, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-33558973

RESUMEN

OBJECTIVES: To evaluate the effect of electric current application on the resin composite-tooth bond strength and hybrid layer of three adhesive systems light-cured by two light-curing units (LCUs). MATERIALS AND METHODS: Human molar teeth were distributed into 12 groups (n=6). Three adhesive systems were used: two-step etch-and-rinse (SB2; Adper Single Bond 2, 3M ESPE); two-step self-etch (CSE; Clearfil SE Bond, Kuraray); and one-step self-etch (SBU; Single Bond Universal, 3M ESPE) applied with (50µA) and without (control; conventional application) electric current, and light-cured with different LCUs. Resin composite blocks (Filtek Z350XT, 3M ESPE) were produced and cut into sticks (~1mm2) for microtensile bond strength (µTBS). Fracture patterns were analyzed on stereomicroscope and classified as cohesive-dentin, cohesive-resin, adhesive, or mixed. Specimens were prepared for scanning electron microscope observation. The hybrid layer analysis was carried out using a confocal laser scanning microscopy (n=2). Data were submitted to three-way ANOVA followed by Tukey's post hoc test (α=0.05). RESULTS: The electric current increased the µTBS for all adhesive systems light-cured with single-emission peak and multiple-emission peak LCUs. Both LCUs presented similar µTBS values. CSE applied under electric current showed the highest µTBS mean values. The adhesive failure pattern was more frequently observed in all groups. The electric current formed long resin tags for all adhesive systems. CONCLUSIONS: The adhesive systems applied under electric current increased the bond strength using single-emission peak and multiple-emission peak LCUs. CLINICAL RELEVANCE: Electric current at 50µA applied throughout the dentin is a safe mode and results in better impregnation of the adhesive systems.


Asunto(s)
Recubrimiento Dental Adhesivo , Resinas Compuestas , Dentina , Recubrimientos Dentinarios , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Cementos de Resina , Resistencia a la Tracción
4.
J Prosthodont ; 25(1): 28-32, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26375599

RESUMEN

PURPOSE: Photodynamic therapy (PDT) appears to be an effective method for the in vitro and in vivo inactivation of Candida spp., but no clinical trials in this context have yet been conducted. The aim of this study was to compare the effect of oral miconazole gel to PDT combined with low-power laser (LPL) therapy in the treatment of denture stomatitis. MATERIALS AND METHODS: Forty participants with clinical and microbiological diagnoses of type II denture stomatitis were randomly allocated to two treatment groups (PDT and miconazole gel), each with 20 individuals. The PDT group was submitted to one session of methylene blue-mediated PDT plus two sessions of low-laser therapy twice a week for 15 days. The miconazole group was submitted to the drug four times a day for 15 days. RESULTS: Forty percent of the patients achieved clinical and microbiological resolution of denture stomatitis after methylene blue-mediated photodynamic inactivation followed by low-laser therapy. The cure rate associated with miconazole was 80% (p < 0.05). Fifteen days after the end of treatment, the recurrence rate was 25% in patients treated with PDT combined with LPL therapy and 12.5% in patients treated with miconazole. CONCLUSION: Miconazole gel provides better results than a protocol combining methylene blue-mediated PDT and LPL therapy in the treatment of type II denture stomatitis.


Asunto(s)
Antifúngicos/uso terapéutico , Terapia por Láser , Miconazol/uso terapéutico , Estomatitis Subprotética/terapia , Candida , Humanos , Azul de Metileno/uso terapéutico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...